Show simple item record

dc.contributor.advisorChávez Paredes, Alejandro
dc.contributor.advisorSologuren Anchante, Rafael Fernando
dc.contributor.authorMendoza Marín, Danny Omar
dc.contributor.authorRengifo Boza, Alexander
dc.date.accessioned2016-09-23T16:38:30Z
dc.date.available2016-09-23T16:38:30Z
dc.date.issued2010
dc.identifier.otherT/617.695/M42
dc.identifier.urihttp://repositorio.unapiquitos.edu.pe/handle/20.500.12737/1915es_PE
dc.description.abstractEl presente estudio tiene como objetivo general determinar el efecto del grabado ácido y el microarenado en la adhesión de los espigos de fibra de vidrio cementados con el sistema RelyX UlOO. El tipo de investigación es Cuantitativa y el diseño de la investigación es Experimental. La muestra estuvo• constituida por 40 piezas dentarias premolares unirradiculares recientemente extraídas en un plazo de 8 meses. El instrumento utilizado fue la ficha de recolección de datos para medir la adhesión de espigos de fibra de vidrio cementados con sistema RelyX U100, validado por juicio de expertos y prueba de validez y confiabilidad. La fuerza de resistencia de adhesión por tracción de los espigos de fibra de vidrio cementados con el sistema RelyX U100 según especificaciones del fabricante, presentó un promedio de•80.23 N, con una desviación típica de± 29.82 N siendo el valor mínimo de 39.20 N y la adhesión máxima de 141.12 N, y por medio de grabado ácido y microarenado se observó un promedio de 102.68 N, con una desviación típica de ±38.29 N, siendo el valor mínimo de 60.72 N y máxima de 217.56 N. Se aplicó la prueba F de Levene para determinar si existe o no igualdad de varianzas, obteniéndose la significancia de 0.636, concluyendo que las varianzas son homogéneas en ambos grupos de estudio. Al aplicar la prueba estadística "t" de Students con n1+ n2 - 2 grados de libertad, se observa que existe diferencia significativa p = 0,0450 (p<0.05) entre las medidas de adhesión por tracción de los espigos cementados con el sistema RelyX U100 con especificaciones del fabricante en comparación de los espigos cementados con grabado ácido y microarenado. Lo que nos permite afirmar que el grabado ácido de la dentina y el microarenado del espigo aumentan la adhesión de los espigos de fibra de vidrio cementados con el sistema RelyX U100.es_PE
dc.description.abstractThe purpose of this study was to determine the effect of the acid etching and microretentions in the adhesion of the glass fiber post cemented with RelyX U100 system. The research is quantitative and research design is experimental. Forty single-rooted human premolar teeth extracted recently within 8 months. The instrument used was the data collection sheet to measure the adhesion of glass fiber post cemented with RelyX UlOO system, validated by expert opinion and test ofvalidity and reliability. The tensile bond strength val u es of glass fiber posts cemented with Rely X U 100 system according to manufacturer's specifications had an average of 80.23 N with a standard deviation of 29.82, minimum value of 39.20 N and the maximum value of 141.12 N, and acid etching and microretentions had an average of 102.68 N, with a standard deviation of ±38.29 N, where the minimum value of 60.72 N and maximum value of 217.56 N. Test Levene's F was applied to determine equal variances, obtaining the significance of 0.636, concluding that the variances are homogeneous in both groups. To applying the statistical test "t" Student' s "t" with n1 + n2 - 2 degrees of freedom, showed significant difference p = 0.0450 (p<0.05)between measures of adhesion by traction of post cemented with RelyX UlOO system with manufacturer's specifications compared with the post cemented with acid etching and microretentions. We can say that the acid etching of dentin and microretentions in the post increase the adhesion of glass fiber post cemented with RelyX UlOO system.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de la Amazonía Peruanaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.sourceUniversidad Nacional de la Amazonía Peruanaes_PE
dc.sourceRepositorio Institucional - UNAPes_PE
dc.subjectAdhesión química de cementos dentaleses_PE
dc.subjectAdhesivos dentaleses_PE
dc.titleEfectos del grabado ácido y el microarenado en la adhesión de espigos cementados con el sistema Relyx U100, in vitro, 2009es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineOdontologíaes_PE
thesis.degree.grantorUniversidad Nacional de la Amazonía Peruana. Facultad de Odontologíaes_PE
thesis.degree.levelTítulo Profecionales_PE
thesis.degree.nameCirujano Dentistaes_PE
thesis.degree.programRegulares_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#3.02.14es_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record