dc.description.abstractEl presente estudio tuvo como objetivo general determinar el límite de angulación vertical antes de producirse distorsiones de la distancia del ápice radiográfico al instrumento endodóntico, la metodología fue de tipo Cuantitativo, Experimental, Transversal Correlacional, Para la realización de esta investigación in vitro fueron seleccionados 20 primeras molares superiores con raíces palatinas integras de la hemiarcada derecha, incluidos en un dispositivo de soporte experimental individual. Los resultados encontrados mostraron variaciones cuando se realizó las diferentes tomas a diferentes angulaciones (0°, 10°, 20° y 30°) y a diferentes distancias (O mm, 0.5 mm, 1 mm, 1.5 mm, 2 mm) del AR-IE, esta fue aumentando conforme aumentaba la angulación. Se observó que la distorsión de la distancia AR-IE aparece a partir de 30° cuando se midió 1 mm. y 1.5 mm y la mayor distorsión se presentó cuando la angulación fue de 30° y la distancia medida fue de 2 mm cuando se considera distorsión a partir de 0.25 mm. En la presente investigación se concluye, que a partir de 30° existe distorsión de la distancia AR-IE clínicamente observable, el cual aumenta cuando la distancia mencionada es mayor.es_PE
dc.description.abstractThis study was as aimed to determine the overall limit of angulation vertical distortions occur before the radiographic apex distance of the endodontic instrument, the methodology was a quantitative, experimental, correlational Cross, To carry out this investigation in vitro were selected 20 first molars with palatal roots integrate the arch included in an individual experimental support device. The results showed variations when they made the different shots at different angles (0°, 10°, 20° and 30°) and at different distances (O mm, 0.5 mm, 1 mm, 1.5 mm, 2 mm) of ARIE, this was increased with increasing the angle. It was noted that the distortion of the distance AR-IE appears from 30° when measured 1 mm and 1.5 mm and most distortion occurs when the angle was 30° and the measured distance was 2 mm when considering distortion from 0.25mm. In the present investigation: is concluded, that from 30° for distortion of the distance AR-IE clinically observable, which increases when the distance mentioned is greater.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfen_US
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de la Amazonía Peruanaes_PE
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.sourceUniversidad Nacional de la Amazonía Peruanaes_PE
dc.sourceRepositorio Institucional - UNAPes_PE
dc.subjectÁpice del dientees_PE
dc.subjectMalformaciones de los dienteses_PE
dc.subjectInstrumentos dentaleses_PE
dc.subjectRadiografía dentales_PE
dc.titleDistorsión vertical de la distancia del ápice radiográfico al instrumento endodóntico en la conductometría según diferentes angulaciones, estudio invitroes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
thesis.degree.disciplineOdontologíaes_PE
thesis.degree.grantorUniversidad Nacional de la Amazonía Peruana. Facultad de Odontologíaes_PE
thesis.degree.levelTílulo Profesionales_PE
thesis.degree.nameCirujano Dentistaes_PE
thesis.degree.programRegulares_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#3.02.14es_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record